|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
Forced Operation ( C/O Model) � To operate the appliance by force in case that the remote controller is lost, the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions. � When the power is supplied while the slide switch is on the forced operation position, or when the slide switch position is switched to the Auto Restarting position (or test operation) or switched from the remote control position to the forced operation position while the power is on, the forced operation is carried out. � When the slide switch position is switched from the forced operation position to the Auto Restarting position or the remote control position, the forced operation is canceled and the appliance stops operating. � The forced operation is carried out in cooling mode with the setting temperature 22°C and the high speed of airflow. � While in forced operation, the key input by the remote controller has no effect and the buzzer sounds 10 times to indicate the forced operation. Forced Operation ( H/P Model) � To operate the appliance by force in case that the remote controller is lost, the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions. � When the power is supplied while the slide switch is on the forced operation position, or when the slide switch position is switched to the Auto Restarting (or test operation) position or switched from the remote control position to the forced operation position while the power is on, the forced operation is carried out. � When the slide switch position is switched from the forced operation position to the Auto Restarting position or the remote control position, the forced operation is canceled and the appliance stops operating. � The forced operation is carried out in cooling mode with the setting temperature 22°C and the high speed of airflow. � In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the operation condition is set according to the intake air temperature as follows. 24°C Intake Air Temp => Cooling Mode Operation, 22°C, High Speed 21°C Intake Air Temp < 24°C => Dehumidification Operation, 23°C, High Speed Intake Air Temp < 21°C => Heating Mode Operation, 24°C, High Speed � While in forced operation, the key input by the remote controller has no effect and the buzzer sounds 10 times to indicate the forced operation. Test Operation Control � To check the condition of the installation when installing the appliance, the appliance is operated at cooling mode, high speed of airflow, compressor-on for 18 min without controlling the room temperature. � Only when the slide switch on the main unit is switched from the remote control position to the test operation position, test operation is carried out. � When the slide switch position is switched to the remote control position while in test operation, the test operation is canceled and the appliance is stopped. When switched to the forced operation position, the test operation is canceled and the forced operation is carried out. � While in test operation, a key can be input by the remote controller. When a key (operation start/stop, operation mode selection, airflow speed selection, temperature control, Jet Cool) is input by the remote controller, the test operation is canceled and the appliance is operated according to the setting by the remote controller.
- 22 -
|
|
 |
> |
|